<Parameter>
<ParameterFamily>altim</ParameterFamily>
<LongName>
plate_door
</LongName>
<Name>
pdoor
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The time in seconds the firmware will wait for the plate door to move to
position.  If the plate door sensor is disabled the firmware will assume that
it has moved to position after this time is elapsed.
</text></DescriptionText>
</Description>
<Type>
uint32
</Type>
<Default>
<UnnumberedList>
<li>4.000 seconds</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 10.000 seconds</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
This parameter is stored as an integer value of milliseconds.  It is entered
by the user in seconds and displayed to the user in seconds. The user may enter
up to three digits after the (optional) decimal point.
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/al_cfg_pds.xml</LinkAddress><LinkTitle>NVS: al pds</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:34 2008 PST
</Updated>
<Links>
</Links>